Some factories may temporarily stop operation due to adjustment of production and air compressors. How to properly handle the air compressors that are shut down, according to the length of the downtime, the following methods should be strictly followed, especially when the temperature is below 0 degrees and high. Seasons or areas of humidity should pay attention to the treatment method. The treatment method for screw air compressor to stop for more than 1 month: 1) Wrap the electrical equipment such as the controller and distribution box of the air compressor with plastic paper or oil paper to prevent gas intrusion; 2) When the air compressor is shut down, the water in the oil cooler and the aftercooler should be completely drained to prevent the cooler from being cracked and damaged under low temperature conditions; 3) If there is any fault before the air compressor stops, it should be repaired and placed again to avoid urgent use in the future; 4) After the air compressor is stopped for two or three days, the condensed water in the oil and gas drum, oil cooler and aftercooler is discharged; The screw air compressor is shut down for more than 3 months. In addition to the above procedures, the following processing is required: 1) Close all openings of the air compressor to prevent moisture and dust from entering; 2) Replace the air compressor oil before decommissioning, and run for 30 minutes. After two or three days, remove the condensate from the air tank and oil cooler; 3) completely discharge the condensate; 4) Place the air compressor in a place with less dust and dry air. Concerned about surprises Label: Treatment method for screw air compressor to stop for more than 1 month Previous: Reasons for motor over-current and temperature rise and countermeasures Next: Solenoid valve manufacturers six working principles cheats to get daily dimensions Hex Wrench Set,Hex Key Socket Set,Best Hex Key Set,Folding Hex Key Set henan horn tools co.,ltd. , https://www.horntoolsltd.com